Giangarlo Scientific
  • sales@giangarloscientific.com

Titrators: HI 84100

Free & Total Sulphur Dioxide Mini-Titrator for Wine Analysis

  • Performs simple titrations in minutes.
  • Lab grade Sulphur Dioxide measurements
  • Small and affordable

The HI 84100 is a low cost, easy to use, microprocessor based automatic titrator that benefits from Hanna’s years of experience as a manufacturer of analytical instruments. It has a simple and reliable peristaltic pump that ensures high dosing repeatability. By performing pump calibration with the provided Hanna stantards, the instrument accuracy is assured. The instrument with a pre-programmed analysis method designed for Free and Total Sulphur Dioxide measurements on wine samples. The instrument has a powerful and effective built-in algorithm to analyze the shape of the electrode response and to determine the reaction completion.This algorithm automates the analysis, makes all the necessary calculations and assures a simple and effective interface for the user. By simply pressing the START STOP button, the instrument will automatically make the titration up to the equivalence point. The result is immediately displayed in convenient units, then the instrument is ready for another titration.

Each HI 84100 mini-titrator is supplied complete with reagents set for 20 titrations, two 50 mL beakers, two 20 mL beakers, scissors, tube set with cap, ORP probe, stir bar, power cable one 30 mL bottle of refill solution, one 1 mL syringe, two sachets of cleaning solution for wine deposits, two sachets of cleaning solution for wine stains and instruction manual.

 

Available Accessories:
HI 70300L | Electrode Storage Solution
HI 70635L | Cleaning Solution for Wine Deposits
HI 70636L | Cleaning Solution for Wine Stains
HI 7082 | Electrode Filling Solution
HI 84100-50 | Titrant Solution 100 mL
HI 84100-51 | Alkaline Reagent 500 mL
HI 84100-52 | Acid Reagent for Total SO2
HI 84100-53 | Acid Reagent for Total SO2

 

Specifications:
Range
0 to 400 ppm SO2
Resolution
1 ppm
Accuracy (@20°C/68°F)
5% of reading
Method
Ripper titrimetric method
Principle
Equivalence point REDOX titration
Sample Volume
50 mL
ORP Electrode
HI 3148B (included)
Pump Debit
0.5 mL/Minute
Stirring Speed
1500 RPM
Environment
0 to 50°C (32 to 122°F): Max 95% RH Non-condensing
Power Supply
220V/50Hz; 10VA
Dimensions
208 x 214 x 163 mm (8.2 x 8.4 x 6.4″) with beaker
Weight
2.2 kg (4.8 lbs.)

 

Resources:
HI 84100 Manual.pdf

Home | Analytical | Environmental | Clinical Life Science | Process | Safety | Wastewater | Service | Contact Us