Giangarlo Scientific
  • sales@giangarloscientific.com

Gas Flow Sensors and Meters

 

 

Model 100, 110, S-110 & S-113 

 

Description

For OEM or laboratory applications, where an affordable flow sensor needs to be installed, the Model 100 is an excellent choice.  Its time-proven turbine design will keep measuring accurately for years with little or no maintenance.  It features a   0-5VDC output standard.  A power adapter or cable assembly (below) is required for operation.

The Model 110 Flo-Meters are great for laboratory benchtop gas applications.  An integrated 3½ digit flow rate display informs the user of actual flow, and the 0-5VDC output can be interfaced to a data acquisition system.  A power adapter (USA unless specified) is included for plug-and-go operation.

The Model S-110 and S-113 Flo-Meters have a wide variety of uses. They too incorporate an LCD, 3½ digit display of flow rate, but can be less expensive than the Model 110. The S-110 has a plastic body with acetal fittings, and the S-113 is constructed from brass & includes brass fittings. A power adapter or cable assembly (below) is required.

Dimensions, (excluding fittings):
Model 100:  2.35″x1.65″x1.50″
Model S-110, S-113:  1.88″x3.00″x1.75″
Model 110:  5.00″x4.50″x5.00″          

Ranges

100 110 S-110 S-113 Flow Range Max. Pressure Drop Standard Fittings
100-3 110-3 S-110-3 S-113-3 20-100 mL/minute 20″ water 1/8″ tube
100-4 110-4 S-110-4 S-113-4 40-200 mL/minute 8″ water 1/8″ tube
100-5 110-5 S-110-5 S-113-5 100-500 mL/minute 2″ water 1/8″ tube
100-6 110-6 S-110-6 S-113-6 200-1000 mL/minute  2″ water 1/8″ tube
100-7 110-7 S-110-7 S-113-7 0.4-2.0 L/minute 2″ water 1/4″ tube
100-8 110-8 S-110-8 S-113-8 1.0-5.0 L/minute 2″ water 1/4″ tube
100-9 110-9 S-110-9 S-113-9 2.0-10.0 L/minute 3″ water 1/4″ tube
100-10 110-10 S-110-10 4.0-20.0 L/minute 3″ water 3/8″ tube
100-11 110-11 S-110-11 10-50 L/minute 3″ water  3/8″ tube
100-12 110-12 S-110-12 20-100 L/minute 3″ water 1/2″ tube
100-13 110-13 S-110-13 40-200 L/minute  5″ water 1/2″ tube
100-14 110-14 S-110-14 100-500 L/minute 20″ water 1/2″ tube

NIST Calibration Certificate is optional at an added cost.

All units calibrated for air unless specified; certain unusual gases or blends may incur added costs.  Call for details.

Units also available calibrated to English (SCFH) units; call for details.

Options and Accessories

100-17 Cable Assembly – 3 foot long cable terminated with pigtail leads.  Includes all cables for input/output.

S-PS-08 – 115VAC (USA) power adapter and output leads.  Order S-PS-18 for 230VAC (European) applications.


Model 50K, 50S, 50D, & 50SD

 

Description

The McMillan Company line of mass flow sensors and meters continues to sell more and more each year.  Why?  Because no other mass flow products on the market maintain such high quality standards at such an affordable price.  All-metal construction.  Calibration certificate standard on all units.  Minimum 96-hour burn-in.  Fast response.  High repeatability.  Years of reliability.   The McMillan Company 50 Series.  We realize that you have a lot of choices for mass flow sensors and meters, so we strive to make a product that you will find superior.

The Model 50S and 50SD are all-stainless steel, and come standard with stainless steel compression fittings.  The Model 50K and 50D feature anodized aluminum construction and come standard with plastic compression fittings unless indicated.  Both the Model 50D and the Model 50SD incorporate a 3½ digit flow rate display and come standard with a NIST-Traceable Certificate.  All models include a 3 foot cable terminated with a connector.  
Either a cable assembly or option package is required for operation (see below).

Wetted Parts

50S/50SD Wetted Parts:   316, 303 & 304 stainless steel.  Stainless steel fittings standard on all ranges.
50K/50D Wetted Parts: 316, 303, & 304 stainless steel, anodized aluminum and Viton®. Ranges 2-10 feature acetal fittings; range 11 has brass fittings; ranges 12-15 have stainless fittings. On ranges 2-10, metal fittings are available at an extra charge.

Dimensions (not including fittings):
50K, 50S: 1.87″x1.03″x3.55″
50D, 50SD: 1.87″x1.03″x5.00″
Call for dimensions on units above 10 L/minute.



Ranges

50K 50S 50D 50SD Flow Range Max. Pressure Drop Standard Fittings
50K-2 50S-2 50D-2 50SD-2 0-20 mL/minute 1″ water 1/8″ tube
50K-3 50S-3 50D-3 50SD-3 0-50 mL/minute 1″ water 1/8″ tube
50K-4 50S-4 50D-4 50SD-4 0-100 mL/minute 2″ water 1/8″ tube
50K-5 50S-5 50D-5 50SD-5 0-200 mL/minute 2″ water 1/8″ tube
50K-6  50S-6 50D-6 50SD-6 0-500 mL/minute 2″ water 1/8″ tube
50K-7 50S-7 50D-7 50SD-7 0-1000 mL/minute 3″ water 1/8″ tube
50K-8 50S-8 50D-8 50SD-8 0-2.0 L/minute 3″ water 1/4″ tube
50K-9 50S-9 50D-9 50SD-9 0-5.0 L/minute 3″ water 1/4″ tube
50K-10 50S-10 50D-10 50SD-10 0-10.0 L/minute 5″ water 3/8″ tube
50K-11 50S-11 50D-11 50SD-11 0-20.0 L/minute 6″ water 3/8″ tube
50K-12 50S-12 50D-12 50SD-12 0-50 L/minute 6″ water 3/8″ tube
50K-13 50S-13 50D-13 50SD-13 0-100 L/minute 6″ water  1/2″ tube
50K-14 …  50D-14 0-200 L/minute 6″ water 1/2″ tube
50K-15 50D-15 0-500 L/minute 6″ water 1/2″ tube

 

NIST Calibration Certificate standard on Model 50D & 50SD, and is optional on Model 50K & 50S at an added cost.

All units calibrated for air unless specified; certain unusual gases or blends may incur added costs.  Call for details.

Units also available calibrated to English (SCFH) units; call for details.

Options and Accessories

Model 90 & 91 In-Line Filter – 20 micron filtering.  Order Model 90 for ranges 2-7; Model 91 for ranges 8-10.

50-C-X Cable Assembly – 3 foot long cable terminated with pigtail leads.  Includes all cables for 0-5VDC output.

A-115VAC Option Package – 115VAC (USA) power adapter & cabling for 0-5VDC. Order A-230VAC for Europe.

B-115VAC Option Package – 115VAC (USA) power adapter & cabling for 4-20 mA. Order B-230VAC for Europe.