FSS Flow Sampling System
| Monitor and
Record Stormwater or Industrial Discharge Flow
|
FEATURES:
|
Product Description
Global Water's Flow Sampling System is a unique water monitoring package. This package includes an easy-to-use lightweight composite water sampler, an open channel flow monitor with dual displays and outputs, and a data recorder that is both Windows and Palm Pilot compatible. This compact package is portable for field installation and fully customizable to meet your monitoring needs.
Water
Sampler
Global Water's flow-proportional water sampler is enclosed in a
rugged, rainproof, lockable carrying container. The water
sampler includes a 2-gallon polyethylene wastewater sample bottle
for collecting composite samples, a peristaltic sampling pump, a
two-knob control panel (no programming required), and a
rechargeable gel cell battery. Also provided is a sample
pickup hose and a battery charger. Optional additions
include glass sample bottles, refrigerated containers, portable
ice containers and more. Visit the WS300 Wastewater Sampler
page for more information on the flow proportional composite
water sampler.
Open
Channel Flow Monitor
Global Water's FC200 Open Channel Flow Monitor is reliable and
accurate for measuring and totalizing open channel flows for all
flumes and weirs, as well as any gravity-type open-channel
flows. The flow monitor is pre-programmed with over 20
different flume and weir characteristics and can also be
programmed for your unique application. The unit measures
water depth with Global Water's highly accurate pressure
transducer and instantly calculates (for display and output)
water flow and totalizer values for any depth-to-flow
relationship in any engineering units. The Open Channel
Flow Monitor is easily set up in the field using a unique
four-button programming system. Visit the FC200 Open
Channel Flow Monitor page for more information.
Flow
Data Recorder
Global Water's flow data recorder includes Windows-based and Palm
Pilot software, which provide many useful features, such as real
time monitoring, measurement interval and engineering unit
selections, station ID, and sensor calibration. The Global
Water Software makes accessing stored data and setting options
easy. The data recorder monitors and logs both flow rate
and total flow for your records. Data downloaded from the
recorder can easily be opened in any PC spreadsheet program for
analysis and graphic presentation. Visit the GL400-1-1
Datalogger page for more information.
Specifications
WS300
Wastewater Sampler
Composite Sample Size: 25 mi to 600 ml as set by user (two
gallon composite sample maximum)
Size: 9"L X 17"W X 22"H
Weight: 22lb (Shipping Weight 24lb)
Operating Temperature: 0-70°C
Materials
Enclosure: Expanded UV protected by PVC
Bottle: Two gallon polyethylene
Sample Tubing: Polyethylene
Logic Timer/Controller: CMOS Solid State (fully potted in
epoxy)
Sample Hose: One 15' nylon reinforced 1/4" ID
polyethylene flexible tubing sections with intake strainer.
Hose may be extended, as required, using standard 1/4"
tubing and fittings.
Sample
Pump
Flow Rate: 1000 ml per minute at 4 ft. head
Type: Peristaltic
Maximum Lift: 22'
Battery
Rechargeable 5 AH Gel Cell. The battery will power the
sampler for a minimum of four months including five 24-hr. storm
events before recharging is required.
FC200
Open Channel Flow Monitor
Rate Display: 6 digit + decimal place, LCD
Totalizer Display: 6 digit + decimal place, LCD
Accuracy: Pressure transducer: +0.2% FS, Flow
Monitor: +0.01% + the depth-flow-table error
Flow Units: CFS, GPM, m3s, MGD
Totalizer: Related to Flow Units
Enclosure: 4 3/4" W x 8" H x 3" D, NEMA 4X
(IP67)
Power: 120 VAC to 240 VAC, optional: Battery powered (Must
be specified at time of ordering)
Pre-defined
Tables
Parshall: 1", 2", 3", 6", 9",
12"
Palmer-Bowlus (4D): 4", 6", 8", 10",
12", 15"
Weir: 45° V notch, 90° V notch, 1' rectangular, 2'
rectangular
H: 0.4HS, 0.6HS, 0.5H, 0.75H, 1.0H, 1.5H, 2.0H
Trapezoidal: 60°
Custom
Table
Equation or look up table provided at time of order. Allow
for longer lead times for custom table entry.
GL400-1-1
Datalogger
Memory: Non-volatile flash memory
Resolution: 12-Bit
Channels: 1-Analog, 1-Pulse
Storage Capacity: 19,500 time and date stamped data points
per channel
Recording Rate: Linear fixed intervals from 1 per second
to every 32,000 seconds (also 0-32,000 minutes, hours and days);
Logarithmic test (for pump and slug testing)
Data Overwrite: Select memory wrap or unwrap (unwrap will
stop logging data once memory is full)
Clock: Synchronizes to the time and date of user's
computer
Operating Temperature: -40° to +170°F
Enclosure: ABS plastic (5" x 3" x 3")
Optional Weather-Proof Enclosure Expanded UV protected PVC
(9" x 7.5" x 4.5")
Optional Battery: 12 Volt, 2.2 A/hr., Rechargeable (Gell
Cell) (Included with Weather-Proof Enclosure)
Weight: 3.5 lbs