
FC200 Open Channel Flow Monitor
| Measure and
Totalize Flows in Open Channels
|
FEATURES:
|
Product Description
Global Water's Open Channel Flow Monitor is reliable and accurate for measuring and totalizing open channel flows for all flumes and weirs, as well as for any gravity-type open-channel flow application. The flow meter measures water depth with Global Water's highly accurate pressure transducer, and the unit's electronic circuitry instantly calculates and displays water flow and totalizer values for any depth-to-flow relationship in any engineering units. The Open Channel Flow Monitor is easy to set up in the field using a unique four-button programming system.
Open Channel Flows
For any open channel that is free flowing, there is a specific
relationship between depth of water and flow rate. Whenever
a given depth occurs, there will always be the same flow.
Therefore, if the flow rate is known for each depth, a
depth-to-flow relationship can be constructed. The Open
Channel Flow Monitor is pre-programmed with depth-to-flow
relationship tables. When the user digitally selects the correct
depth-to-flow relationship for an application, the Open Channel
Flow Monitor's LCD screen automatically displays accurate flow
rate measurements for any depth that is reached. This water
flow is averaged over time to display total flow.
When using a primary device to measure flow, such as a measuring flume or weir, there is a mathematical relationship between depth and flow. When measuring flow in a channel that does not have a primary device, the depth-to-flow table can be constructed by measuring the flow at several different depths, using Global Water's Flow Probe.
Depth Measurement
Global Water's Open Channel Flow Monitor measures flow depth with
the highly-accurate WL 400 Water Level Sensor, which is a fully
submersible water level sensor constructed of stainless
steel. The standard level range is from 0 to 3' of water,
which provides for accurate flow measurements even with depth
change is as small as a fraction of an inch. The pressure
transducer is mounted slightly below the "zero" flow
depth of the channel, upstream from the throat of the flume or
weir. For open channels with no primary device, the sensor
is mounted below the lowest expected water depth. The water
level sensor has a 2-wire 4-20 mA signal, so the flow computer
can be mounted several hundred feet away, if required. The
sensor and computer can be connected with standard, twisted-pair
signal wire.
Display and Outputs
The Open Channel Flow Monitor displays flow rate on a large
6-digit LCD screen. The totalized output is shown on a
second LCD display. The display reads in user-defined units
of flow, including mgd, csf, gpm, m3s.
The Flow Monitor also produces an analog 4-20 mA output signal that is proportional to flow. This can be used for chart recorders, dataloggers, or as an input to telemetry or process control systems. In addition, the meter has a flow-proportional output signal for triggering water samplers.
Digital Flow
Computer
The Global Water Open Channel Flow Monitor has powerful internal
electronic circuitry that calculates and totalizes flow.
Desired engineering units and depth-flow relationships (from over
20 pre-defined tables) can easily be selected using the unit's
four front panel push buttons. User programming does not
require the unit's enclosure to be opened. The unit's
manual includes programming information, including depth-to-flow
tables for all standard flumes and weirs.
Enclosure
The enclosure is made of weatherproof injection molded
plastic. It is suitable for use in a wide variety of
environments. The enclosure can be wall-mounted and fitted
with conduit for sensor and power connections, if required.
Specifications
Rate Display: 6
digit + decimal place, LCD
Totalizer Display: 6 digit + decimal place, LCD
Accuracy: Pressure transducer: +0.2% FS, Flow
Monitor: +0.01% + the depth-flow-table error
Flow Units: CFS, GPM, m3s, MGD
Totalizer: Related to Flow Units
Enclosure: 4 3/4" W x 8" H x 3" D, NEMA 4X
(IP67)
Power: 120 VAC to 240 VAC, optional: Battery powered (Must
be specified at time of ordering)
Pre-defined Tables
Parshall: 1", 2", 3", 6", 9",
12"
Palmer-Bowlus (4D): 4", 6", 8", 10",
12", 15"
Weir: 45° V notch, 90° V notch, 1' rectangular, 2'
rectangular
H: 0.4HS, 0.6HS, 0.5H, 0.75H, 1.0H, 1.5H, 2.0H
Trapezoidal: 60°
Custom Table
Equation or look up table provided at time of order. Allow
for longer lead times.