Wall Mounted Process Controllers
| Product Series |
Chlorine Controller |
pH Controller |
ORP (mV) Controller |
EC/TDS Controller |
Control Type | Alarm Function |
4-20 mA Output |
Pump |
| PCA 300 | Free | ON/OFF, Proportional | | | ||||
| PCA 301 | Total | ON/OFF, Proportional | | | ||||
| HI 9910 | | ON/OFF, Proportional | | | ||||
| HI 9911 | | ON/OFF, Proportional | | | ||||
| HI 9920 | | ON/OFF, Proportional | | | ||||
| HI 9912 | | | ON/OFF, Proportional | | ||||
| HI 9923 | | EC | ON/OFF | | ||||
| HI 9931 | EC | ON/OFF, Proportional | | | ||||
| HI 9934 | TDS | ON/OFF, Proportional | | | ||||
| HI 9913 | | EC | ON/OFF, Proportional | | ||||
| HI 9935 | | TDS | ON/OFF, Proportional | | ||||
| BL 7916 | | Proportional | | | | |||
| BL 7917 | | Proportional | | | | |||
| HI 21 | | ON/OFF, Proportional | | |||||
| HI 22 | | ON/OFF, Proportional | | |||||
| HI 8002 | | EC | ON/OFF, Proportional | | ||||
| HI 8614 | | |||||||
| HI 8615 | | |||||||
| HI 8936 | | |||||||
| HI 98143 | | |||||||
| Code | Chlorine Controller |
pH Controller |
ORP Controller |
EC/TDS Controller |
Control Type | Alarm Function |
4-20 mA Output |
Pump |
TECHNICALLY SUPERIOR
Hanna's wall mounted pH, ORP, and conductivity controllers are specifically designed to meet your process control requirements. The controllers come equipped with power relays operating at a maximum of 2A (240V). Electrodes can be installed quickly and easily. Simply plug the universal BNC or DIN connector over the socket and twist it into a secured position. This feature greatly improves the reliability of your instrumentation by assuring a positive connection. Accurate measurements are displayed on a large LCD, enabling the operator to check the controller readings easily.
ALARM FEATURE
The Hanna wall mounted series of controllers incorporate a triple contact alarm system that allows the user to select whether the alarm contacts will be in a normally open or normally closed position. When the measured value of the meter is out of range, the alarm is activated. The alarm will also be activated if the unit loses power. When activated, the alarm contacts will open or close, triggering the mechanism of your choice, whether a buzzer, light or any other electrical device. The alarm is a necessity when the installation is in a remote location and corrective action must be taken immediately in the event of an out-of-range condition.
ISOLATED RECORDER OUTPUT
The ability to record the data from the process you are monitoring greatly enhances process troubleshooting. By simply connecting a recorder to the controller's output terminals you are able to acquire a hard copy of the readings for demonstrative or analytical purposes. The recorder output terminals are isolated from the controller circuitry to avoid any interference and are user-switchable between 0 to 20 mA or 4 to 20 mA.
HIGH IMPEDANCE INPUT
The pH and ORP controllers come with high impedance 1012 ohm direct input from the electrode, ideal for applications with a distance of up to 33 feet (10 meters). The greater the distance between the controller and the sample, the greater the chance that line noise will occur, causing faulty readings. Use an AmpHelฎ pH electrode to greatly enhance the input signal allowing high accuracy at distances of up to 165 feet (50 meters).
QUALITY CONSTRUCTION
These controllers are housed in a rugged, modular, fiber-reinforced polypropylene housing. Polypropylene has properties that will resist the harmful effects of most chemicals. When in operation, and with the transparent protective cover installed, the units comply with the IP55 standards. The modular design isolates the controller circuitry from all contacts, assuring that there is no noise interference. The use of this rugged design protects the unit from the tough conditions associated with industrial environments, ensuring long and trouble-free operation.
SIMPLE INSTALLATION
The wall mounted controllers have mounting holes molded into the housing to assure simple, quick and secure installation without the need for additional hardware. Once all electrical connections are made, the protective cover can be installed over the front panel, making it possible to perform all adjustments without disassembly of the unit. Temperature probes can be installed if ATC is desired (pH models). Pumps to be used in conjunction with the controller simply plug into the controller's 110/115 or 220/240 input and will be powered up through the unit's internal power supply