Panel Mounted Process Controllers

 
Product
Series
pH EC/
TDS
ORP (mV) Menu
Driven Display
Control Type 4-20 mA
Output
Alarm
Function
RS232
HI 504 ON/OFF, PID
pH 500     ON/OFF, Proportional
pH 502     ON/OFF, PID, Proportional
mV 600     ON/OFF, Proportional
mV 602     ON/OFF, PID, Proportional
HI 700   EC   ON/OFF, PID, Proportional  
HI 705   TDS   ON/OFF, PID, Proportional  
HI 710   EC/TDS   ON/OFF, PID, Proportional  
HI 931500       ON/OFF    
HI 931501       ON/OFF    
HI 932500       ON/OFF    
HI 8710       ON/OFF  
HI 8711       ON/OFF  
HI 8720       ON/OFF  
HI 8931   EC     ON/OFF  
HI 943500   EC     ON/OFF  
HI 8510* *            
HI 8512*     *        
HI 8001 EC   ON/OFF
Code pH EC/TDS ORP Menu
Driven Display
Control Type 4-20 mA
Output
Alarm
Function
RS232
* Indicator only

TECHNICAL SUPERIORITY

Hanna's panel mounted pH, ORP, and conductivity controllers are designed to meet your most demanding process control requirements. The controllers come equipped with a power relay operating at a maximum of 2A (240V). Where a direct electrode input is not suitable, the controller is available with a 4-20 mA input from the amplifier. This feature greatly improves the safety of your instrumentation and plant. Accurate measurements are displayed on a large LCD, enabling the operator to check the controller readings easily. These units have sophisticated, built-in self-diagnostic functions that allow the operator to check whether a malfunction has originated in the instrument itself, or in the outside connection. This saves valuable time and money, particularly in the monitoring of important processes. In the event of a malfunction, the operator can determine the origin and rectify the situation before any costly errors occur. The unique Self-Diagnostic Error Prevention System makes the Hanna process meters superior to conventional controllers.

ALARM FEATURE

All Hanna controllers incorporate an alarm warning capability. When the measured value of the meter is out of the user-specified range, the alarm is activated. When activated, the alarm contacts close, triggering the mechanism of your choice, whether a buzzer, light or any other electrical connection. The alarm feature is a necessity when the installation is in a remote location and corrective action must be taken immediately in the event of an out-of-range condition.

RECORDER OUTPUT

The ability to record data from the process you are monitoring greatly enhances process troubleshooting. By simply connecting a recorder to the controller's output terminals (choose between 0 to 20 mA or 4 to 20 mA according to your needs), you are able to acquire a hard copy for demonstrative or analytical purposes.

LOW OR HIGH IMPEDANCE INPUT

Hanna pH and ORP controllers come in two different models to meet all requirements. The E model, has a high impedance 1012 Ohm direct input from an electrode, ideal for connections with a distance of up to 33 feet (10 meters). The T model, however, is recommended for distances greater than 33 feet (10 meters) and should be used with a 4 to 20 mA transmitter. The greater the distance between the controller and the sample, the greater the chance you have of line noise causing erroneous readings. Using a transmitter greatly enhances the input signal, thus allowing high accuracy at distances of up to 1000 feet (300 meters).

CONSENT FEATURE

The consent contact allows you to be sure that the ORP dosing occurs only when the pH value is correct. This assures that the pH is within a specified range before any dosing of oxidizing or reducing agents occurs. This will prevent any overdosing of chemicals, a very important cost-effective feature in many systems such as cyanide oxidation and chromium reduction.

QUALITY CONSTRUCTION

The controllers are housed in sturdy aluminum casings with ABS plastic front panels. The mounting brackets that are supplied with the meter, can be installed securely and quickly. When in operation, and with the transparent protective cover installed, the units comply with the IP54 standards. The use of this rugged design protects the unit from the tough conditions associated with industrial environments, ensuring long and trouble-free operation.

LED INDICATORS

The LEDs are on the front panel light to indicate the correct operational mode. The LEDs also blink at different rates to indicate multiple modes occurring simultaneously. This feature allows the user to evaluate the controller from a distance and clearly read which mode it is in.